Код ошибки Описание
E000
  • The thermistor (TH1, TH2) has poor contact or an open circuit
  • The fixing heater (H1) has an open circuit
  • The thermal switch (TSW1) has turned on
  • The triac is faulty
  • The DC controller PCB is faulty
  • E001
  • The thermistor (TH1, TH2) has a short circuit
  • The triac is faulty
  • The DC controller PCB is faulty
  • E002
    E003
    The thermistor (TH1, TH2) has poor contact or an open circuit

  • The fixing heater (H1) has an open circuit
  • The thermal switch (TSW1) has turned on
  • The triac is faulty
  • The DC controller PCB is faulty
  • E004
  • The triac has a short circuit
  • The DC controller PCB is faulty
  • E010
  • The main motor (M1) is faulty
  • The DC controller PCB is faulty
  • E013
  • The waste toner feedscrew is locked
  • The waste toner feedscrew lock sensor (PS8) is faulty
  • The DC controller PCB is faulty
  • E030
  • The total copy counter has an open circuit
  • The DC controller PCB is faulty
  • E031
  • The accessories counter has an open circuit
  • The DC controller PCB is faulty
  • (E202) No code indication. Keys are disabled

  • The scanner home position sensor (PS1) is faulty
  • The scanner motor (M2) is faulty
  • The DC controller PCB is faulty
  • E208
  • The mirror home position sensor (PS3) is faulty
  • The mirror motor (M4) is faulty
  • The DC controller PCB is faulty
  • E210
  • The lens home position sensor (PS2) is faulty
  • The lens motor (M3) is faulty
  • The DC controller PCB is faulty
  • E220
  • The lamp regulator PCB is faulty
  • The DC controller PCB is faulty
  • E261
  • The power supply frequency is faulty
  • The power supply PCB is faulty
  • E710
    E711
  • The DC controller PCB is faulty
  • E712
  • The DC controller PCB is faulty
  • The ADF controller PCB is fault
  • The ADF cable is faulty
  • E717
  • The DC controller PCB is faulty
  • The Remote Diagnostic Device II PCB is faulty
  • E800
  • The auto power-off circuit has an open circuit
  • The DC controller PCB is faulty
  • E805
  • The exhaust fan (FM2, FM4) is faulty
  • The DC controller PCB is faulty
  • E821
  • The ozone filter is clogged
  • The cleaner thermistor (TH3) has poor contact or an open circuit
  • The DC controller PCB is faulty