A |
B |
Неисправность |
Причина |
Примечание |
|
Fujiko-ODA The true disposal method is indicated as a machine. — Especially a different portion from the disposal method of a former machine is. system fail/sub system fail (I have a person in charge indicate Fail which requires hard / mechanism part exchange) |
Fujiko-ODA True detection conditions are indicated as a machine. — Especially the portion the detection conditions of a former machine are indicated to be as they are is. It is cautious of system fail/sub system fail |
008 |
153 |
(IOT JAM) Feed Jam 1 (Early Feed Jam ) The paper arrival to a Reg position is too early |
Needlessness |
The paper arrival to a Reg position is too early |
008 |
155 |
(IOT JAM) Regi Sensor On Jam Reg Sensor is in On state in Warming up |
|
008 |
156 |
(IOT JAM) Regi Sensor Off Jam A paper does not come for a Fuser position from a Reg position within regulation time |
|
008 |
176 |
Tray 1 Regi Sensor On Jam Imari: REGI SNR ON JAM (Tray) GINGA: Tray1 Missfeed Jam |
The same as that of user disposal |
Even if it carries out regulation time progress from a Tray1 Feed start, a Reg sensor does not turn on
Sensor of IOT Sub detects only by one. Although a display is different for every tray, this will display for the Jam Zone information sent apart from Chain Link. (Imari: Jam detection specifications K4) No.2 / Regi Sensor On Jam / Feed Tray#1-4 |
008 |
180 |
Comm: Duplex In Sensor On Jam (C6-1) Dup Miss Feed Jam |
Duplex In Sensor is not turned on in Duplex conveyance operation
Since the timer of operation from a sensor changes with paper sizes at the time of Duplex Module printing, there is two kinds of REGI SENSOR ON JAM. (Imari: Jam detection specifications K4) No.2 / Regi Sensor On Jam/ DUP |
008 |
314 |
Between DCSYS-DM Duplex Unit was separated after the I/F unusual power supply injection |
|
Duplex Unit Fail was detected |
009 |
413 |
Toner Black 1 Near Empty |
The same as that of user disposal |
When Dispense Motor of Black becomes circumference sky of regulation time closely
Toner Status * HID 980420 *HID 980430 |
009 |
460 |
Toner Black Quality Life End (only display) |
Needlessness |
CRU life operation was set up for not stopping by the panel, and after IOT detected Toner Warning, data transmission was performed by 100 sheets |
009 |
670 |
New Toner Detected – K |
|
|
009 |
671 |
New Toner Detected – C |
009 |
672 |
New Toner Detected – M |
009 |
673 |
New Toner Detected – Y |
009 |
909 |
Topo: EP Cartridge Type Missmatch |
The same as that of user disposal |
Unentered |
009 |
910 |
Topo: EP Cartridge Not Installed |
009 |
938 |
GINGA: Black Toner Cartridge Detached |
When K toner cartridge is not set
030606 Delete from Comm (Fu/Ta/Sh) |
010 |
105 |
Fuser Exit Sensor On Jam Imari: F/U EXIT SNR ON JAM (at the time of F/U discharge) GINGA: Exit In Jam |
Ginga: After RegRoll turns on, even if it carries out regulation time progress, an Exit sensor does not turn on
With no “Imari: Jam detection specifications K4″ correspondence |
010 |
106 |
010 |
112 |
GINGA: Exit Out Early Jam |
Ginga: After an Exit sensor turns on, an Exit sensor does not turn off within regulation time |
010 |
128 |
Duplex Pre Regi Sensor On Jam |
Topo: The paper arrival to a Reg position from a Duplex Sensor position is too early |
010 |
132 |
Duplex Path 1 Sensor On Jam |
A paper is not discharged from a Duplex Sensor position within regulation time, or Duplex Sensor is in On state in Warming up |
010 |
164 |
Regi.SNR On Jam (C6-2) “Dup Miss Feed Jam” (not wait) |
Topo: A paper does not come for a Reg position from a Duplex Sensor position within regulation time sheeta: Duplex Out Sensor is not turned on in Duplex conveyance operation |
010 |
347 |
“OCT failure”: Offset Fail (OCT) |
|
Failure detection / wearing detection cannot be carried out in the “Imari” present condition |
010 |
398 |
Fuser Fan Fail (U4-9) |
If not repaired in power supply OFF/ON, it is FUSER Fan exchange |
The logical sum OR of a FUSER FAN lock signal and a LVFAN lock signal is taken, and it considers as a FAN LOCK FAIL signal Ginga: When Fuser FAN does not turn at regular number of rotations
Discharge and Billing all the papers that have already Feed(ed) |
010 |
420 |
Fuser ASSY Change Soon GINGA: Fuser Unit Pre Warning |
The same as that of user disposal |
When PV reached the regulation value and becomes a life closely |
011 |
108 |
OCT Jam 1 (paper attainment is not carried out at OCT) |
[ from an Exit Sensor position / to an OCT Sensor position / in a paper ] within regulation time |
011 |
109 |
OCT Jam 2 (paper attainment is not carried out at OCT) |
A paper is not discharged from an OCT Sensor position within regulation time, or OCT Sensor is On state in Engine Warming up |
012 |
300 |
Faceup Tray was opened during printing |
|
When Cover Interlock Open of FaceUpTray was detected in JOB, Faceup Tray was opened during printing in Standard mode or OCT mode |
012 |
301 |
Faceup Tray was closed during printing |
|
Faceup Tray was closed during printing by Faceup Tray |
012 |
951 |
OCT_FULL_STACK |
|
Full Stack (OCT) was detected |
012 |
952 |
FaceUP Tray Open |
Although the output to Facedown Tray or OCT was specified, it detected that Faceup Tray was open |
012 |
953 |
FaceUP Tray Close |
Although the output to Faceup Tray was specified, it detected that Faceup Tray had closed |
012 |
965 |
FIN STAPLER PIN NEAR EMPTY Imari: Stapler Near Empty GINGA: Stapler Near Empty Topo: Stapler Near Empty |
Low Staple Sensor OFF |
When ON of Low Staple Sensor is detected at the time of – power supply injection and Interlock Close in one of the following cases and ON of Low Staple Sensor is detected just before – Staple Head Close operation implementation |
012 |
969 |
IOT Center Tray Full |
H-Tra IOT Full Paper Sensor continues and it is between 1sec(s) OFF |
H-Tra IOT When Full Paper Sensor detects ON by continuation between 10sec(s)
Since a Center tray turns into a tray different from a base when Light Finisher is attached, 7-969 assigns a code independently |
016 |
450 |
SMB host name duplication |
A host name is changed |
PC which has the same host name existed on the network |
016 |
452 |
IP address duplication |
An IP address is changed |
PC which has the same IP address existed on the network |
016 |
453 |
IP address acquisition failure from a DHCP server |
An IP address is set up (the acquisition from a DHCP server is not performed) |
IP address acquisition went wrong from the DHCP server |
016 |
454 |
Renewal of Dynamic DNS-dynamic goes wrong |
Needlessness |
Needlessness |
016 |
460 |
A FULL state is detected at the time of HD access. The error of which FULL is canceled also for the waiting for time |
|
|
016 |
500 |
SMTP Server Address Resolution Fail for Mail IO |
- |
|
016 |
501 |
POP Server Address Resolution Fail for Mail IO |
- |
|
016 |
502 |
POP Authentication Fail for Mail IO |
- |
|
016 |
503 |
SMTP Server Address Resolution Fail for Redirector |
- |
|
016 |
504 |
POP Server Address Resolution Fail for Redirector |
- |
|
016 |
505 |
POP Authentication Fail for Redirector |
- |
|
016 |
701 |
A PLW deconstructivism memory is insufficient |
Imari: Since a PLW memory is fixation, if it can lower resolution, it will be lowered |
The shortage of a memory was detected at the time of ART EX use
Imari: The memory for “print log” PLW processing of a job is insufficient |
016 |
702 |
1 page was uncompressible |
A memory is extended, resolution is lowered or it is made printing guarantee mode (printing guarantee mode — PLW) in PCL, “a PCL heap memory / band buffer ratio” is made 1:2 or more setup (Chainlink 801-916 of “O2AP”) |
Shortage of the print page buffer which has not been compressed 1 page was detected |
016 |
703 |
Un-establishing and the invalid confidential box number were specified at the time of E-Mail reception |
1. Establish an E-mail transmitting 2. Relevance box to effective box |
At the time of E-mail reception, un-establishing and an invalid confidential box state are detected, and a job end is carried out |
016 |
704 |
Confidential box full (the number of the maximum documents was exceeded around one box) is detected, and a job end is carried out |
An unnecessary document is deleted and processing is performed again |
At the time of HD access, a FULL state is detected and a job end is carried out |
016 |
705 |
Security accumulation cannot be carried out without HD |
It checks whether it has equipped with HDD. When a trouble occurs at the time of wearing, it checks whether operation of a security print is wrong |
Security accumulation could not be carried out without HDD, but registration of a security print went wrong |
016 |
706 |
The job end of having exceeded confidential and the number of the maximum users of a proof print is detected and carried out |
Unnecessary document/user are deleted and it is execution of a re-print |
At the time of HD access, a FULL state is detected and a job end is carried out |
016 |
707 |
A proof print is impossible (conditions in which a proof print is possible, such as HD-less/HD failure, do not gather) |
It checks whether it has equipped with HDD When a trouble occurs at the time of wearing, it checks whether operation of a proof print is wrong |
You could not accumulate without HDD but registration of a proof print went wrong |
016 |
709 |
PLW Command Error An error is detected by PLW deconstructivism |
Job is canceled and it performs again |
The ART EX command error occurred during PLW processing |
016 |
710 |
Delayed Print Fail |
|
|
016 |
716 |
The file which carries out a spool by the “TIFF file injustice” TIFF exceeded disk capacity |
With no necessity |
|
016 |
719 |
A PCL deconstructivism memory is insufficient |
PCL memory size is increased |
The shortage of a memory is detected at the time of PCL use |
016 |
720 |
PCL Command Error An error is detected by PCL deconstructivism |
Job is canceled and it performs again |
A PCL command error occurs during PCL processing |
016 |
721 |
Other errors |
I have the same job performed again, the state of an error is checked, and it looks for support of Support G |
The error which is not expected during print processing |
016 |
726 |
A “automatic judging error” Auto SW automatic judging was not able to be carried out |
Fixed selection of the Decomposer is carried out |
Print language automatic judging error |
016 |
728 |
Tag which is not mounted in a “TIFF file injustice” picture file deployment library is included |
- |
|
016 |
729 |
The number of “TIFF file injustice” colors and the number of pixels were specified exceeding the maximum of the effective range |
- |
|
016 |
730 |
“ART command error” The command which is not supported by ART was detected |
A non-supporting command is deleted and re-printed out of data |
ART IV command error
Although the “gtemul” command is a command of the meaning of “changing to the print mode of an option cartridge”, in multi-PDL, a print language change cannot do it Error log needlessness “print log” ART command error. Processing was stopped |
016 |
731 |
“TIFF file injustice” TIFF data is way piece by the middle |
- |
|
016 |
732 |
“Form composition error” In emulation, when the specified form is not registered, the data itself is not printed |
- |
Deconstructivism detects that the specified form is not registered |
016 |
744 |
It is contained in PDF to which the function which is not supported was sent |
A visitor is requested to have you print via a driver from Acrobat Reader |
In PDF1.3, Transparency or JBIG2 was contained in the PDF file |
016 |
748 |
At the time of confidential box access, a FULL state is detected and a job end is carried out |
The capacity of HDD is vacated and it is execution of a re-print |
At the time of HD access, a FULL state is detected and a job end is carried out
In Print Job, since the job end only of a part to have been stored in HD is printed and carried out, what is defined as “un-giving a definition / Job Fail” is used In Copy Job, since a message is displayed and it waits for user directions, what is defined as “Others/Notice” (3-981) is used Description of the “Fault item” sequence is united above and corrected |
016 |
749 |
The syntax error of a “JCL/PJL syntax error” JCL/PJL command was detected |
A command is corrected |
The syntax error of a JCL/PJL command was detected |
016 |
751 |
PDF Error |
The same as that of user disposal |
When a syntax error, use of the command non-given a definition, a parameter error, breakage of a PDF file, and the internal error of PDF deconstructivism occur during PDF Bridge processing |
016 |
752 |
PDF Short of Memory |
The shortage of a memory was detected during PDF Bridge processing |
016 |
753 |
PDF Password Mismatched |
Password protection is carried out. When the password of UI panel setup and the password specified by XPJL (it sets up by Contents Bridge) are not in agreement by the case where a PDF file is processed |
016 |
754 |
PDF LZW Not Installed |
LZW compression technology was used in the state where the “Contents Bridge extension kit” is not installed. PDF file processed by PDF Bridge |
016 |
755 |
PDF Print Prohibited |
Printing prohibition specification was carried out when a PDF file is processed |
016 |
757 |
Auditron – Invalid User |
|
016 |
758 |
Auditron – Disabled Function |
|
016 |
759 |
Auditron – Reached Limit |
|
016 |
760 |
The error occurred in “PS Decompose error” deconstructivism pause processing |
A job is broadcast again (the check of execution environment / data is required at the time of a recurrence) |
The error occurred in deconstructivism pause processing |
016 |
761 |
“Image output” FIFO EMPTY error |
It prints in speed priority mode. When this cannot be printed, either, it prints in printing guarantee mode |
Picture extension error (FIFO EMPTY error) |
016 |
762 |
“Decomposer absence” The functions (a print language, print utility etc.) which are not mounted were required (decomposer specified in PJL or Auto SW is not mounted) |
Fixed selection of the Decomposer is carried out |
The functions (a print language, print utility etc.) by which print language non-carrying mounting is not carried out were required (decomposer specified in PJL or Auto SW is not mounted) |
016 |
764 |
SMTP server connection error |
Needlessness |
SMTP-server response code: 421 or 451
“Result code” of an error log character sequence is prescribed by RFC |
016 |
765 |
SMTP server HD full |
The same as that of user disposal |
SMTP-server response code: 452 |
016 |
766 |
The problem of an SMTP server file system |
SMTP-server response code: 552 |
016 |
767 |
E-mail address address injustice |
SMTP-server response code: 550 or 551 |
016 |
768 |
Transmitting agency address injustice (login error) |
It error-answers by the “MAIL FROM:” command of an SMTP protocol |
016 |
769 |
An SMTP server un-corresponds to DSN |
Response code of the “EHLO” command of an ESMTP protocol: There is “no DSN” in the support command list received from 502 or the server |
016 |
781 |
Server connection is not made at the time of “network connection error at time of network scan” transmission |
1. Main part From 2. transmission place server which sets up correctly a “subnet mask” and a “gateway” “ping” etc. 3.Win 95 which checks that M/C can be seen From a UNIX machine to a transmission place server It checks that it is connectable by ftp |
Connection establishment with a FTP server goes wrong |
016 |
796 |
Control of mail printing by user setup |
|
Imari-MF PL2/AP or subsequent ones In E-mail reception, since the mail which does not have an appending document in the state of a setup of “not printing a header and the text” was received, mail was canceled In the case of the above-mentioned case, it leaves Mail IO to the purport and error history report which canceled mail at ChainLink A mounting top job is not generated |
016 |
797 |
Output place injustice of reception mail |
- |
It is after change Imari-MF PL2/AP to 127 – 027 Job is not generated E-mail to Box and E-mail to Fax drop(ed). When E-mail is received by this specification |
016 |
798 |
No TrustMarking Option |
- |
When Decomposer call(ed) S-Image lib, the error without HD came on the contrary |
016 |
799 |
Print Instruction Fail detected in PLW |
|
When a print parameter error (003-747) is found by PLW |
016 |
981 |
A FULL state is detected at the time of HD access. The error of which FULL is not canceled for the waiting for time, either finishing [ 1 page or more accumulation ] |
HDD partition size of the service which corresponds if nonavoidable with user disposal is made large |
|
016 |
982 |
A FULL state is detected at the time of HD access. The error of which FULL is not canceled for the waiting for time, either (1 page cannot be accumulated) |
HDD partition size of the corresponding service is made large |
When HDD is judged to be full by the job, the precedence accumulation job, and the interruption job |